Restart a specific SCAN listener
Check current scan listener status: $ srvctl status scan_listener SCAN Listener LISTENER_SCAN1 is enabled SCAN listener LISTENER_SCAN1 is running on node grac2 SCAN Listener LISTENER_SCAN2 is enabled SCAN listener LISTENER_SCAN2 is not running SCAN Listener LISTENER_SCAN3 is enabled SCAN listener LISTENER_SCAN3 is running on node grac2 Restart scan Listener LISTENER_SCAN2: $ srvctl start scan_listener -i 2 Verify new SCAN listener status: $ srvctl status scan_listener SCAN Listener LISTENER_SCAN1 is enabled SCAN listener LISTENER_SCAN1 is running on node grac2 SCAN Listener LISTENER_SCAN2 is enabled SCAN listener LISTENER_SCAN2 is running on node grac1 SCAN Listener LISTENER_SCAN3 is enabled SCAN listener LISTENER_SCAN3 is running on node grac2
Hi Helmut,
Your blog is very useful !
Thanks
Slim
very useful blog
Nice blog and guided very well….